Class |
EN ISO 1716 |
EN 50399 (20,5 KW flam source for B2ca, Cca, Dca; 30KW for B1ca) |
EN 61034-2 |
EN 60754-2 |
EN 60332-1-2 |
||||||
PCS |
THR1200S |
Peak HRR |
FIGRA |
FS |
TSP1200S |
Peak SPR |
Flaming droplets |
Transmittance |
Conductivity and pH |
H |
|
Aca |
<=2.0 |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
B1ca |
/ |
<=10 |
<=20 |
<=120 |
<=1.75 |
/ |
/ |
/ |
/ |
/ |
<425 mm |
B2ca |
/ |
<=15 |
<=30 |
<=150 |
<=1.5 |
/ |
/ |
/ |
/ |
/ |
<425 mm |
Cca |
/ |
<=30 |
<=60 |
<=300 |
<=2 |
/ |
/ |
/ |
/ |
/ |
<425 mm |
Dca |
/ |
<=70 |
<=400 |
<=1300 |
/ |
/ |
/ |
/ |
/ |
/ |
<425 mm |
Eca |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
<425 mm |
Fca |
NPD |
||||||||||
s1 |
|
|
|
|
|
<=50 |
<=0.25 |
|
|
|
|
s1a |
|
|
|
|
|
<=50 |
<=0.25 |
|
>=80% |
|
|
s1b |
|
|
|
|
|
<=50 |
<=0.25 |
|
>=60%<80% |
|
|
s2 |
|
|
|
|
|
<=400 |
<=1.5 |
|
|
|
|
s3 |
Products for which no performance is declared or which do not comply with the s1 and s2 criteria. |
||||||||||
d0 |
|
|
|
|
|
|
|
no droplets occur within 1200 s |
|
|
|
d1 |
|
|
|
|
|
|
|
longer than 10 s occur within 1200 s |
|
|
|
d2 |
Products for which no performance is declared or which do not comply with the d0 and d1 criteria. |
||||||||||
a1 |
|
|
|
|
|
|
|
|
|
<2.5; pH>4.3 |
|
a2 |
|
|
|
|
|
|
|
|
|
<10; pH>4.3 |
|
a3 |
Products for which no performance is declared or which do not comply with the a1 and a2 criteria. |